<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-24 17-37-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 48 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 63 kHz 11553 3,2286
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 4,82 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 63 kHz MIN: 12 kHz % above 76 kHz: 3,2286 Acquired: 2026.08.24 17.36.50 Total samples: 11553 Equivalent time: 0:09:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,1 dBr MIN: 3,3 dBr AVE: 4,82 dBr % above 12,2 dBr: 0,0 Last value: 5,1 dBr (2026.08.24 17.36.49) 17.22 17.24 17.26 17.28 17.30 17.32 17.34 17.36 0 2 4 6 Pm [dBr]